WIPP Conceptual Design Report. Addendum D.A Report to Holmes and Narver, Inc., Anaheim, California on Alternative Energy Sources for Waste Isolation Pilot Plant, Carlsbad, New Mexico

WIPP Conceptual Design Report. Addendum D.A Report to Holmes and Narver, Inc., Anaheim, California on Alternative Energy Sources for Waste Isolation Pilot Plant, Carlsbad, New Mexico

Author:

Publisher:

Published: 1977

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

This report presents the results of a technical and economic analysis of alternative methods of meeting the energy needs of a proposed Waste Isolation Pilot Plant (WIPP) to be located in southeastern New Mexico. The WIPP is a facility for underground storage of radioactive wastes in a deep salt bed. The report analyzes a total of sixteen possible methods for meeting WIPP energy requirements, consisting of purchased electricity and on-site generation in various combinations from full purchased to full on-site.


WIPP Conceptual Design Report. Addendum J. Support Equipment in the High Level Waste Facility of the Waste Isolation Pilot Plant

WIPP Conceptual Design Report. Addendum J. Support Equipment in the High Level Waste Facility of the Waste Isolation Pilot Plant

Author:

Publisher:

Published: 1977

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

The Aerojet Manufacturing Company (AMCO) received a contract in November 1976 to provide consulting services in assisting Holmes and Narver, Incorporated with the conceptual designs, cost estimates, and schedules of equipment used to handle waste casks, to decontaminate waste canisters and to overpack damaged or highly contaminated waste canisters for the Waste Isolation Pilot Plant (WIPP). Also, the layout of the hot cell in which canister handling, overpack and decontamination takes place was to be reviewed along with the time and motion study of the cell operations. This report has been prepared to present the results of the efforts and contains all technical and planning data developed during the program. The contents of this report are presented in three sections: (1) comments on the existing design criteria, equipment conceptual designs, hot cell design and time and motion studies of projected hot cell activities; (2) design descriptions of the equipment concepts and justification for varying from the existing concept (if a variation occurred). Drawings of each concept are provided in Appendix A. These design descriptions and drawings were used as the basis for the cost estimates; and (3) schedule projections and cost estimates for the equipment described in Section 2. Detail cost estimate backup data is provided in Appendix B.


WIPP Conceptual Design Report. Addendum F. HVAC Systems Energy Analysis for Waste Isolation Pilot Plant

WIPP Conceptual Design Report. Addendum F. HVAC Systems Energy Analysis for Waste Isolation Pilot Plant

Author:

Publisher:

Published: 1977

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

This report presents the results of a technical and economic analysis of alternative methods of meeting the heating, ventilating, and air conditioning requirements of the Waste Isolation Pilot Plant (WIPP) facilities proposed to be constructed in southeastern New Mexico. This report analyzes a total of ten WIPP structures to determine the most energy and economic efficient means of providing heating, ventilating, and air conditioning services. Additional analyses were performed to determine the merits of centralized versus dispersed refrigeration and heating facilities, and of performing supplemental domestic hot water heating with solar panels.


WIPP Conceptual Design Report. Addendum A. Design Calculations for Waste Isolation Pilot Plant (WIPP).

WIPP Conceptual Design Report. Addendum A. Design Calculations for Waste Isolation Pilot Plant (WIPP).

Author:

Publisher:

Published: 1977

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

The design calculations for the Waste Isolation Pilot Plant (WIPP) are presented. The following categories are discussed: general nuclear calculations; radwaste calculations; structural calculations; mechanical calculations; civil calculations; electrical calculations; TRU waste surface facility time and motion analysis; shaft sinking procedures; hoist time and motion studies; mining system analysis; mine ventilation calculations; mine structural analysis; and miscellaneous underground calculations.


Waste Isolation Pilot Plant (WIPP) Conceptual Design Report. Part I

Waste Isolation Pilot Plant (WIPP) Conceptual Design Report. Part I

Author:

Publisher:

Published: 1977

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

The pilot plant is developed for ERDA low-level contact-handled transuranic waste, ERDA remote-handled intermediate-level transuranic waste, and for high-level waste experiments. All wastes placed in the WIPP arrive at the site processed and packaged; no waste processing is done at the WIPP. All wastes placed into the WIPP are retrievable. The proposed site for WIPP lies 26 miles east of Carlsbad, New Mexico. This document includes the executive summary and a detailed description of the facilities and systems. (DLC).


WIPP Conceptual Design Report. Addentum I. Soils and Foundation Investigation for Proposed Waste Isolation Pilot Plant, Eddy County, New Mexico

WIPP Conceptual Design Report. Addentum I. Soils and Foundation Investigation for Proposed Waste Isolation Pilot Plant, Eddy County, New Mexico

Author:

Publisher:

Published: 1977

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

This report presents the results of a soils and foundation investigation for the proposed Waste Isolation Pilot Plant (WIPP) located in Section 21, Township 22 South, Range 31 East, N.M.P.M., Eddy County, New Mexico. The purpose of this investigation was to determine the physical characteristics of the subsoils in order to provide foundation design recommendations. The investigation was performed and the report prepared in accordance with the requirements received from John West Engineering Company and Mr. Bill Wowak, Sandia Laboratories. These were: (1) statement of work for WIPP soils investigation program, and (2) WIPP soil investigation revised drill hole location.