Evaluation of the Tricon Retained Soil Wall System

Evaluation of the Tricon Retained Soil Wall System

Author: Highway Innovative Technology Evaluation Center (U.S.)

Publisher: ASCE Publications

Published: 2002-01-01

Total Pages: 142

ISBN-13: 9780784475171

DOWNLOAD EBOOK

Prepared by the Highway Innovative Technology Evaluation Center, a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the Tricon System for use as a technically viable, precast, mechanically stabilized earth-retaining wall system. The evaluation considered material, design, construction, performance, and quality assurance information outlined in the HITEC Protocol.


Evaluation of the Inter-Lok Retaining Wall System

Evaluation of the Inter-Lok Retaining Wall System

Author: Highway Innovative Technology Evaluation Center (U.S.)

Publisher: ASCE Publications

Published: 2002-01-01

Total Pages: 130

ISBN-13: 9780784475102

DOWNLOAD EBOOK

Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the INTER-LOK System for use as a technically viable, precast mechanically stabilized earth retaining wall system. The evaluation was conducted based on design, construction, performance, and quality assurance information outlined in the HITEC Protocol. The INTER-LOK System features a cross-shaped, segmental precast concrete facing panel connected to metallic rebar and anchor plate type of soil reinforcement attached to the facing panels by a keyplate that interlocks with the facing panels.


Evaluation of the Maccaferri Terramesh System Retaining Wall

Evaluation of the Maccaferri Terramesh System Retaining Wall

Author: Highway Innovative Technology Evaluation Center (U.S.)

Publisher: ASCE Publications

Published: 2002-01-01

Total Pages: 94

ISBN-13: 9780784475201

DOWNLOAD EBOOK

Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF/IIEC Innovation Center. This report describes a HITEC evaluation designed to determine the basic capabilities and limitations of the Terramesh Retaining Wall System for use as a technically viable, mechanically stabilized earth, retaining wall system. The evaluation was conducted based on material, design, construction, performance, and quality assurance mainformation outlined in the HITEC Protocol. The Terramesh System, supplied by Maccaferri, Inc.,Øfeatures a Gabion basket facing of various configurations and metal double-twisted grid type of soil reinforcement, which is manufactured integrally with the basket facing blocks.


Environmental Technology Verification Report for the Plasma Enhanced Melter

Environmental Technology Verification Report for the Plasma Enhanced Melter

Author:

Publisher: ASCE Publications

Published: 2003-01-01

Total Pages: 92

ISBN-13: 9780784475225

DOWNLOAD EBOOK

Prepared by the Environmental Technology Evaluation Center (EvTEC), a service center of CERF/IIEC. This Technology Verification report describes the nature and scope of the environmental evaluation of the performance of the Plasma Enhanced Melter? (PEM?) system for waste treatment. The evaluation was conducted through a cooperative program established in 1998 between the Washington State Department of Ecology, Integrated Environmental Technology Inc., Allied Technology Group, and the Civil Engineering Research Foundation. The goal of this report is to provide potential users and purchasers of the PEM? system with information they need to make more informed decisions regarding the performance of PEM? as an equivalent or alternative to incineration for treating hazardous waste.