Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Soils Using GC-ECD
Author: Marianne E. Walsh
Publisher:
Published: 1999
Total Pages: 52
ISBN-13:
DOWNLOAD EBOOKRead and Download eBook Full
Author: Marianne E. Walsh
Publisher:
Published: 1999
Total Pages: 52
ISBN-13:
DOWNLOAD EBOOKAuthor: Marianne E. Walsh
Publisher:
Published: 1998
Total Pages: 40
ISBN-13:
DOWNLOAD EBOOKAuthor: Marianne E. Walsh
Publisher:
Published: 1998
Total Pages: 74
ISBN-13:
DOWNLOAD EBOOKAn analytical method for the determination of nitroaromatic, nitramine, and nitrate ester explosives and Co-contaminants in water was developed based on SPE (solid-phase extraction) and GC-ECD (gas chromatograph-electron capture detector). Water samples are preconcentrated using either cartridge or membrane SPE followed by elution with acetonitrile. The acetonitrile extract is compatible with both liquid and gas chromatography, thereby allowing direct comparison of concentration estimates obtained by different methods of determination. Quantitative GC analyses were obtained by using deactivated direct-injection-port liners, short wide-bore capillary columns. and high linear carrier gas velocities. Recoveries from spiked samples were 90% or greater for each of the nitroaromatics and nitrate esters, and greater than 70% for nitramines and amino-nitrotoluenes. Estimates of analyte concentrations in well-water extracts from military sites in the United States and Canada analyzed by GC-ECD and the standard HPLC (high performance liquid chromatography) method showed good agreement for the analytes most frequently detected (HMX octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, RDX hexahydro-1,3,5-trinitro-1,3,5-triazine, TNT 2,4,6-trinitrotoluene, and TNB 1,3,5-trinitrobenzene). The GC method provides lower method detection limits for most analytes than HPLC, but accurate calibration is more difficult. The ultraviolet (UV) detector used for the HPLC analysis has much greater linear range than the ECD used for GC analysis. In addition. the GC instrumentation requires more care than the LC. Specifically the injection port liner must be changed frequently to maintain accurate determination of the nitramines. Because the sample preparation technique yields extracts that are compatible with both GC and HPLC analysis, confirmation of analyte presence can be obtained based on different physical properties.
Author:
Publisher:
Published: 1998
Total Pages: 0
ISBN-13:
DOWNLOAD EBOOKAn analytical method for the determination of nitroaromatic, nitramine, and nitrate ester explosives and Co-contaminants in water was developed based on SPE (solid-phase extraction) and GC-ECD (gas chromatograph-electron capture detector). Water samples are preconcentrated using either cartridge or membrane SPE followed by elution with acetonitrile. The acetonitrile extract is compatible with both liquid and gas chromatography, thereby allowing direct comparison of concentration estimates obtained by different methods of determination. Quantitative GC analyses were obtained by using deactivated direct-injection-port liners, short wide-bore capillary columns. and high linear carrier gas velocities. Recoveries from spiked samples were 90% or greater for each of the nitroaromatics and nitrate esters, and greater than 70% for nitramines and amino-nitrotoluenes. Estimates of analyte concentrations in well-water extracts from military sites in the United States and Canada analyzed by GC-ECD and the standard HPLC (high performance liquid chromatography) method showed good agreement for the analytes most frequently detected (HMX octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, RDX hexahydro-1,3,5-trinitro-1,3,5-triazine, TNT 2,4,6-trinitrotoluene, and TNB 1,3,5-trinitrobenzene). The GC method provides lower method detection limits for most analytes than HPLC, but accurate calibration is more difficult. The ultraviolet (UV) detector used for the HPLC analysis has much greater linear range than the ECD used for GC analysis. In addition. the GC instrumentation requires more care than the LC. Specifically the injection port liner must be changed frequently to maintain accurate determination of the nitramines. Because the sample preparation technique yields extracts that are compatible with both GC and HPLC analysis, confirmation of analyte presence can be obtained based on different physical properties.
Author: Jared Anderson
Publisher: John Wiley & Sons
Published: 2016-02-29
Total Pages: 2148
ISBN-13: 3527333746
DOWNLOAD EBOOKEndlich ein Forschungsleitfaden für Wissenschaftler des Fachgebiets, die neue Methoden entwickeln oder einsetzen. Dieses Handbuch umfasst fünf thematische Bände und bietet damit einen umfassenden Überblick über das Fachgebiet. Erläutert werden Grundlagen, die Methodenentwicklung und hochkarätige Anwendungen für alle wichtigen Analyseverfahren, darunter chromatische Verfahren, Techniken in den Bereichen Elektromigration und Membranen. Dieses Referenzwerk umfasst ein breites Spektrum und legt den Schwerpunkt auf Entwicklungen für die Zukunft. Damit ist es ein Muss für Forscher und eine wertvolle Wissensquelle für Studenten im Hauptstudium und Studienabsolventen.
Author: Alan Dole Hewitt
Publisher:
Published: 2001
Total Pages: 32
ISBN-13:
DOWNLOAD EBOOKOn-site determination of nitroaromatic, nitramine, and nitrate ester explosives compounds in soils was performed using a field-portable gas chromatograph (GC)equipped with a thermionic ionization detector (TID)selective for compounds with nitro functional groups. Soil samples were extracted with acetone. A 1 microliter volume of the filtered soil extract was manually injected into the GC, allowing for the rapid qualification and quantification of the suite of explosives that often coexist in soils at military training facilities and other defense-related sites. Good agreement was established for the concentrations of several explosives analytes when this method of analysis was compared to either high-performance liquid chromatography (Method 8330)or GC electron capture (Method 8095)analysis. Comparisons were performed for sample extracts and for soil subsample replicates distributed for on-site preparation and analysis during a field verification test performed under the auspices of the U.S. Environmental Protection Agency's Environmental Technology Verification (ETV)Program.
Author: Alan Dole Hewitt
Publisher:
Published: 1999
Total Pages: 24
ISBN-13:
DOWNLOAD EBOOKAuthor:
Publisher:
Published: 2000
Total Pages: 86
ISBN-13:
DOWNLOAD EBOOKAuthor: Donnell R. Christian, Jr.
Publisher: CRC Press
Published: 2022-06-20
Total Pages: 491
ISBN-13: 1000594270
DOWNLOAD EBOOKForensic Investigation of Clandestine Laboratories, Second Edition is fully updated to address all aspects of the forensic investigation of clandestine laboratories. While, the first edition focused on the domestic clandestine manufacture of contraband substances, this edition expands the scope to more fully address the clandestine manufacture of explosives that have become a threat that is global in nature. In clandestine laboratory operations, equipment is often simple, household chemical products are utilized, and the education of the operators basic. In fact, most of the time these elements individually are perfectly legal to sell and possess. However, the combination of all these elements is what becomes the scene of illicit activity and a criminal operation. In response to the increase in use of homemade explosive mixtures by terrorists, both domestically and internationally, the section clandestine manufacture of explosives is greatly enhanced. Topics are presented in a manner which, while detailed, will not compromise the tactics, techniques, or procedures utilized by law enforcement and military personnel in their ability to combat the clandestine manufacture of contraband substances and the battle against domestic and international terrorism. Key features: • Examines tell-tale signs to look for in recognizing a clandestine lab • Outlines how to safely process the site of a clandestine lab • Details how to analyze collected evidence in the examination laboratory • Provides guidelines as to what to derive from the physical evidence • Offers specific tactics to effectively present the opinions associated with evidence that has been collected during the investigation in a written report, military style briefing or to a jury in a legal proceeding. Forensic Investigation of Clandestine Laboratories, Second Edition guides the reader through the process of recognizing these illegal manufacturing operations. Then it examines the methods as to how to compile the volume of associated evidence into a package that can be presented in a court of law, or to military commanders for decisive action. It is an invaluable resource, that will prove useful to chemistry lab technicians, forensic investigators, fire and first responder professionals, military personnel, police investigative agencies and narcotics units, and lawyer trying cases involving clandestine labs.
Author: Jehuda Yinon
Publisher: Elsevier
Published: 2013-10-22
Total Pages: 323
ISBN-13: 1483140059
DOWNLOAD EBOOKThe Analysis of Explosives surveys the principles of the various analytical methods, describes how these methods are used for the analysis of explosives, and reviews the major analytical work carried out in this field. Organized into 15 chapters, this book begins with the classification of explosives. Subsequent chapters discuss the different methods for the analysis of explosives. The detection and identification of explosive residues and hidden explosives are also explained. This monograph will be useful as a reference book for chemists in analytical and forensic laboratories, as well as a textbook for graduate students in analytical chemistry and forensic sciences.