The Impact of Safety Analyses on the Design of the Hanford Waste Vitrification Plant

The Impact of Safety Analyses on the Design of the Hanford Waste Vitrification Plant

Author:

Publisher:

Published: 1993

Total Pages: 9

ISBN-13:

DOWNLOAD EBOOK

Accident analyses are being performed to evaluate and document the safety of the Hanford Waste Vitrification Plant (HWVP). The safety of the HWVP is assessed by evaluating worst-case accident scenarios and determining the dose to offsite and onsite receptors. Air dispersion modeling is done with the GENII computer code. Three accidents are summarized in this paper, and their effects on the safety and the design of the HWVP are demonstrated.


Documentation of Hanford Site Independent Review of the Hanford Waste Vitrification Plant Preliminary Safety Analysis Report. Revision 3

Documentation of Hanford Site Independent Review of the Hanford Waste Vitrification Plant Preliminary Safety Analysis Report. Revision 3

Author:

Publisher:

Published: 1993

Total Pages: 298

ISBN-13:

DOWNLOAD EBOOK

Westinghouse Hanford Company (WHC) is the Integrating Contractor for the Hanford Waste Vitrification Plant (HWVP) Project, and as such is responsible for preparation of the HWVP Preliminary Safety Analysis Report (PSAR). The HWVP PSAR was prepared pursuant to the requirements for safety analyses contained in US Department of Energy (DOE) Orders 4700.1, Project Management System (DOE 1987); 5480.5, Safety of Nuclear Facilities (DOE 1986a); 5481.lB, Safety Analysis and Review System (DOE 1986b) which was superseded by DOE order 5480-23, Nuclear Safety Analysis Reports, for nuclear facilities effective April 30, 1992 (DOE 1992); and 6430.lA, General Design Criteria (DOE 1989). The WHC procedures that, in large part, implement these DOE requirements are contained in WHC-CM-4-46, Nonreactor Facility Safety Analysis Manual. This manual describes the overall WHC safety analysis process in terms of requirements for safety analyses, responsibilities of the various contributing organizations, and required reviews and approvals.


Interaction Analysis Method for the Hanford Waste Vitrification Plant

Interaction Analysis Method for the Hanford Waste Vitrification Plant

Author:

Publisher:

Published: 1993

Total Pages: 12

ISBN-13:

DOWNLOAD EBOOK

In order to anticipate potential problems as early as possible during the design effort, a method for interaction analysis was developed to meet the specific hazards of the Hanford Waste Vitrification Plant (HWVP). The requirement for interaction analysis is given in DOE Order 6430.1B and DOE-STD-1021-92. The purpose of the interaction analysis is to ensure that non-safety class items will not fail in a manner that will adversely affect the ability of any safety class item to perform its safety function. In the HWVP there are few structures, equipment, or controls that are safety class. In addition to damage due to failure of non-safety class items as a result of natural phenomena, threats to HWVP safety class items include the following: room flooding from firewater, leakage of chemically reactive liquids, high-pressure gas impingement from leaking piping, rocket-type impact from broken pressurized gas cylinders, loss of control of mobile equipment, cryogenic liquid spill, fire, and smoke. The time needed to perform the interaction analysis is minimized by consolidating safety class items into segregated areas. Each area containing safety class items is evaluated, and any potential threat to the safety functions is noted. After relocation of safety class items is considered, items that pose a threat are generally upgraded to eliminate the threat to the safety class items. Upgrading is the preferred option when relocation is not possible. An example will illustrate the method and application in the phased design, procurement, and construction environment of the HWVP.