Multiphase Flow Rate MeasurementUsing a Novel Conductance Venturi Meter

Multiphase Flow Rate MeasurementUsing a Novel Conductance Venturi Meter

Author: ʻAbbās Ḥasan

Publisher:

Published: 2010

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

Multiphase flows, where two or even three fluids flow simultaneously in a pipe are becoming increasingly important in industry. Although much research has been done to measure the phase flow rates of two-phase flows using a Venturi meter, accurate flow rate measurements of two phase flows in vertical and horizontal pipes at different flow regimes using a Venturi meter remain elusive. In water continuous multiphase flow, the electrical conductance technique has proven attractive for many industrial applications. In gas-water two phase flows, the electrical conductance technique can be used to measure the gas volume fraction. The electrical conductance is typically measured by passing a known electrical current through the flow and then measure the voltage drop between two electrodes in the pipe. Once the current and the voltage drop are obtained, the conductance (or resistance) of the mixture, which depends on the gas volume fraction in the water, can then be calculated. The principal aim of the research described in this thesis was to develop a novel conductance multiphase flow meter which is capable of measuring the gas and the water flow rates in vertical annular flows and horizontal stratified gas water two phase flows. This thesis investigates the homogenous and separated (vertical annular and horizontal stratified) gas-water two phase flows through Venturi meters. In bubbly(approximately homogenous) two phase flow, the universal Venturi meter (nonconductance Venturi) was used in conjunction with the Flow Density Meter, FDM (which is capable of measuring the gas volume fraction at the inlet of the Venturi) to measure the mixture flow rate using the homogenous flow model. Since the separated flow in a Venturi meter is highly complex and the application of the homogenous flow model could not be expected to lead to highly accurate results, a novel conductance multiphase flow meter, which consists of the Conductance Inlet Void Fraction Meter, CIVFM (that is capable of measuring the gas volume fraction at the inlet of the Venturi) and the Conductance Multiphase Venturi Meter, CMVM (that is capable of measuring the gas volume fraction at the throat of the Venturi) was designed and manufactured allowing the new separated flow model to be used to determine the gas and the water flow rates. A new model for separated flows has been investigated. This model was used to calculate the phase flow rates of water and gas flows in a horizontal stratified flow. This model was also modified to be used in a vertical annular flow. The new separated flow model is based on the measurement of the gas volume fraction at the inlet and the throat of the Venturi meter rather than relying on prior knowledge of the mass flow quality x. Online measurement of x is difficult and not practical in nearly all multiphase flow applications. The advantage of the new model described in this thesis over the previous models available in the literature is that the new model does not require prior knowledge of the mass flow quality which makes the measurement technique described in this thesis more practical.


Multiphase Flow Metering

Multiphase Flow Metering

Author: Gioia Falcone

Publisher: Elsevier

Published: 2009-11-16

Total Pages: 340

ISBN-13: 0080558844

DOWNLOAD EBOOK

Over the last two decades the development, evaluation and use of MFM systems has been a major focus for the Oil & Gas industry worldwide. Since the early 1990's, when the first commercial meters started to appear, there have been around 2,000 field applications of MFM for field allocation, production optimisation and well testing. So far, many alternative metering systems have been developed, but none of them can be referred to as generally applicable or universally accurate. Both established and novel technologies suitable to measure the flow rates of gas, oil and water in a three-phase flow are reviewed and assessed within this book. Those technologies already implemented in the various commercial meters are evaluated in terms of operational and economical advantages or shortcomings from an operator point of view. The lessons learned about the practical reliability, accuracy and use of the available technology is discussed. The book suggests where the research to develop the next generation of MFM devices will be focused in order to meet the as yet unsolved problems. The book provides a critical and independent review of the current status and future trends of MFM, supported by the authors' strong background on multiphase flow and by practical examples. These are based on the authors' direct experience on MFM, gained over many years of research in connection with both operators and service companies. As there are currently no books on the subject of Multiphase Flow Metering for the Oil & Gas industry, this book will fill in the gap and provide a theoretical and practical reference for professionals, academics, and students.* Written by leading scholars and industry experts of international standing* Includes strong coverage of the theoretical background, yet also provides practical examples and current developments* Provides practical reference for professionals, students and academics


Phase Flow Rate Measurements of Annular Flows

Phase Flow Rate Measurements of Annular Flows

Author: Qahtan Al-Yarubi

Publisher:

Published: 2010

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

In the international oil and gas industry multiphase annular flow in pipelines and wells is extremely important, but not well understood. This thesis reports the development of an efficient and cheap method for measuring the phase flow rates in two phase annular and annular mist flow, in which the liquid phase is electrically conducting, using ultrasonic and conductance techniques. The method measures changes in the conductance of the liquid film formed during annular flow and uses these to calculate the volumetric and mass flow rates of the liquid film. The gas velocity in the core of the annular flow is measured using an ultrasonic technique. Combined with an entrainment model and the liquid film measurements described above, the ultrasonic technique enables the volumetric flow rate of the gas in the core and the volumetric and mass flow rates of entrained liquid droplets to be measured. This study was based on experimental work and the use of modelling techniques. The practical investigation comprised a series of experiments conducted on a purpose built flow loop in which the test section was a Perspex pipe of 50mm ID. The experimental work was limited to two-phase air-water flow. The flow loop was specifically designed to accommodate the different instruments and subsystems designed in this investigation including bespoke flow meters and a film extraction system. Most flow loop controls were automated using a MATLAB program. Reference measurement of the total water flow rate was made using a calibrated turbine flow meter and of the air flow rate using a calibrated rotameter. For the combined ultrasonic/conductance method investigated in this thesis, the velocity of the gas in the core was found using a novel Ultrasonic Flow Meter (USFM). The positioning and arrangement of the transducers have never been used previously. The flow velocity of the liquid film and the thickness of the film were measured using a novel Conductance Flow Meter (CFM). The CFM measured the liquid film thickness using novel wall conductance probes. By cross correlating the signals from a pair of such probes the film velocity was obtained. Good agreement of the experimental results obtained from the CFM and USFM with results published in the literature was found. Although not investigated experimentally in the work described in this thesis, annular flows encountered in the oil industry may contain a liquid phase comprising a mixture of oil and water. For such flows, the volume fractions of the oil and water can be measured using an automated bypass system developed during this project. The bypass system periodically extracts part of the liquid film, measures its density and then releases the sample back into the pipeline. The liquid phase volume fractions are determined from this density measurement which can be performed more than once per minute. An entrainment model was developed, which is required by the ultrasonic/conductance flow metering technique described in this thesis, in which the mass fraction of the liquid flowing as entrained droplets in the core can be determined from the liquid film thickness and velocity measurements. A mathematical model was also developed to describe the properties of the liquid film, such as liquid velocity profile within the film, and the model?s results were found to agree with the experimental results obtained during the project and also with previous work cited in the literature. The complexity of this latter model was reduced by making a number of simplifying assumptions, which are presented and discussed in the thesis, including the assumption that in annular flow there is a dynamic balance liquid entrainment and droplets being deposited back onto the film. The combination of the designed CFM and USFM with the bypass tube and the entrainment model offer the opportunity for a?wet gas? flow meter to be developed to measure two and three phase annular flows at relatively low cost and with enhanced accuracy. Such a device would have the advantage that it would by substantially smaller than systems using separators and it could even be retrofitted onto off-shore platforms. The integration of the subsystems developed in this project into a single system capable of giving on-line measurements of annular flow would be a major benefit to the author?s sponsor, Petroleum Development of Oman.


Method and System for Measuring Multiphase Flow Using Multiple Pressure Differentials

Method and System for Measuring Multiphase Flow Using Multiple Pressure Differentials

Author:

Publisher:

Published: 2001

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

An improved method and system for measuring a multiphase flow in a pressure flow meter. An extended throat venturi is used and pressure of the multiphase flow is measured at three or more positions in the venturi, which define two or more pressure differentials in the flow conduit. The differential pressures are then used to calculate the mass flow of the gas phase, the total mass flow, and the liquid phase. The method for determining the mass flow of the high void fraction fluid flow and the gas flow includes certain steps. The first step is calculating a gas density for the gas flow. The next two steps are finding a normalized gas mass flow rate through the venturi and computing a gas mass flow rate. The following step is estimating the gas velocity in the venturi tube throat. The next step is calculating the pressure drop experienced by the gas-phase due to work performed by the gas phase in accelerating the liquid phase between the upstream pressure measuring point and the pressure measuring point in the venturi throat. Another step is estimating the liquid velocity in the venturi throat using the calculated pressure drop experienced by the gas-phase due to work performed by the gas phase. Then the friction is computed between the liquid phase and a wall in the venturi tube. Finally, the total mass flow rate based on measured pressure in the venturi throat is calculated, and the mass flow rate of the liquid phase is calculated from the difference of the total mass flow rate and the gas mass flow rate.


Multiphase Flow Handbook, Second Edition

Multiphase Flow Handbook, Second Edition

Author: Efstathios Michaelides

Publisher: CRC Press

Published: 2016-10-26

Total Pages: 1559

ISBN-13: 1315354624

DOWNLOAD EBOOK

The Multiphase Flow Handbook, Second Edition is a thoroughly updated and reorganized revision of the late Clayton Crowe’s work, and provides a detailed look at the basic concepts and the wide range of applications in this important area of thermal/fluids engineering. Revised by the new editors, Efstathios E. (Stathis) Michaelides and John D. Schwarzkopf, the new Second Edition begins with two chapters covering fundamental concepts and methods that pertain to all the types and applications of multiphase flow. The remaining chapters cover the applications and engineering systems that are relevant to all the types of multiphase flow and heat transfer. The twenty-one chapters and several sections of the book include the basic science as well as the contemporary engineering and technological applications of multiphase flow in a comprehensive way that is easy to follow and be understood. The editors created a common set of nomenclature that is used throughout the book, allowing readers to easily compare fundamental theory with currently developing concepts and applications. With contributed chapters from sixty-two leading experts around the world, the Multiphase Flow Handbook, Second Edition is an essential reference for all researchers, academics and engineers working with complex thermal and fluid systems.


Flow Measurement

Flow Measurement

Author: Bela G. Liptak

Publisher: CRC Press

Published: 2020-06-30

Total Pages: 222

ISBN-13: 1000110036

DOWNLOAD EBOOK

Fully illustrated with diagrams, tables, and formulas, Flow Measurement covers virtually every type of flow meter in use today. Béla G. Lipták speaks on Post-Oil Energy Technology on the AT&T Tech Channel.


Multiphase Production

Multiphase Production

Author: Jean Falcimaigne

Publisher: Editions OPHRYS

Published: 2008

Total Pages: 200

ISBN-13: 9782710809135

DOWNLOAD EBOOK

Annotation This book presents the fundamentals of multiphase production with regard to flow simulations in multiphase pipelines, multiphase pumping and multiphase metering. It gives a large range of information on approaches and technologies which can be used today. It is designed for engineers involved in field development, but also for petroleum engineering students.


Temperature Effect in Multiphase Flow Meter Using Slotted Orifice Plate

Temperature Effect in Multiphase Flow Meter Using Slotted Orifice Plate

Author: Dohar Jono Sihombing

Publisher:

Published: 2015

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

Multiphase flow metering is one of the major focuses to develop in oil and gas industries. A combination of slotted orifice plate and electrical impedance technique was investigated in order to provide further development of a new type of multiphase flow meter. Flow visualization was conducted in this study to show the performance of the slotted orifice plate to homogenize the mixture flow and continued with the pattern flow discussion. The visualization studied showed that the slotted orifice plate can be applied as a flow conditioner for two-phase flow in the pipe in many patterns flow. An existing pattern flow map based on the velocity of the each component in the mixture showed that the flow regime is a volumetric flow rate and gas volume fraction (GVF) dependant. Temperature affected the measurement results based on the mixture conductivity behavior. Using a combination of linearization technique and curve fit method, the effect of the temperature to the measurement results can be eliminated for GVF range from 2.5% to 97.5%. The slotted orifice characteristics were then investigated with using the calibration factor, Euler number, and Morrison number with respect to differential pressure and pressure of the mixture flow. The electronic version of this dissertation is accessible from http://hdl.handle.net/1969.1/155098