Large Break Loss of Coolant Severe Accident Sequences at the HFIR (High Flux Isotope Reactor).

Large Break Loss of Coolant Severe Accident Sequences at the HFIR (High Flux Isotope Reactor).

Author:

Publisher:

Published: 1990

Total Pages: 30

ISBN-13:

DOWNLOAD EBOOK

An assessment of many potential HFIR severe accident phenomena was conducted during the HFIR design effort, and many severe accident mitigating features were designed into the plant. These evaluation typically incorporated a bounding'' or highly conservative analysis approach and employed tools and techniques representative of the state of knowledge in the mid-1960s. Recently, programs to address severe accident issues were initiated at the Oak Ridge National Laboratory (ORNL) to support the HFIR probabilistic risk assessment (PRA) and equipment qualification and accident management studies. This paper presents the results of environment condition calculations conducted to evaluate a response of HFIR's heat exchanger cell environment to a double-ended rupture of a 0.25 m diameter coolant loop downstream of the circulating pump and check valve. The confinement calculations were performed using an atmospheric fission product source for the heat exchanger cell consistent with, but more conservative than that stipulated in Regulatory Guide 1.89. The results of the calculations indicate that the heat exchanger cell atmospheric temperature peaks at 377 K 225 seconds into the transient and then begins decreasing at approximately 1.7 K per minute. 8 refs., 5 figs.


Large Break Loss-of-coolant Accident Analyses for the High Flux Isotope Reactor

Large Break Loss-of-coolant Accident Analyses for the High Flux Isotope Reactor

Author:

Publisher:

Published: 1989

Total Pages: 10

ISBN-13:

DOWNLOAD EBOOK

The US Department of Energy's High Flux Isotope Reactor (HFIR) was analyzed to evaluate it's response to a spectrum of loss-of-coolant accidents (LOCAs) with potential for leading to core damage. The MELCOR severe accident analysis code (version 1.7.1) was used to evaluate the overall dynamic response of HFIR. Before conducting LOCA analyses, the steady-state thermal-hydraulic parameters evaluated by MELCOR for various loop sections were verified against steady-state operating data. Thereafter, HFIR depressurization tests were simulated to evaluate the system pressure change for a given depletion in coolant inventory. Interesting and important safety-related phenomena were observed. The current analyses (which should be considered preliminary) that occur over a period from 1 to 3 seconds do not lead to core wide fuel melting. Core fluid flashing during the initial rapid depressurization does cause fuel temperature excursions due to adiabatic-like heatup. 3 refs., 4 figs.


Review

Review

Author: Oak Ridge National Laboratory

Publisher:

Published: 1985

Total Pages: 696

ISBN-13:

DOWNLOAD EBOOK