Groundwater Quality Assessment Plan for Single-Shell Waste Management Area B-BX-BY at the Hanford Site

Groundwater Quality Assessment Plan for Single-Shell Waste Management Area B-BX-BY at the Hanford Site

Author:

Publisher:

Published: 2000

Total Pages: 72

ISBN-13:

DOWNLOAD EBOOK

Pacific Northwest National Laboratory conducted a first determination groundwater quality assessment at the Hanford Site. This work was performed for the U.S. Department of Energy, Richland Operations Office, in accordance with the Federal Facility Compliance Agreement during fiscal year (FY) 1996-1997. The purpose of the assessment was to determine if waste from the Single-Shell Tank (SST) Waste Management Area (WMA) B-BX-BY had entered the groundwater at levels above the drinking water standards (DWS). The resulting assessment report documented evidence demonstrating that waste from the WMA has impacted groundwater quality (Narbutovskih 1998). The WMA is located in the northwest corner of the 200 East Area and consists of the 241-B, 241-BX, and 241-BY Tank Farms and ancillary waste systems (Figure 1.1). The unit is regulated under Resource Conservation and Recovery Act (RCRA) interim-status regulations (40 CFR 265, Subpart F) and was originally placed in assessment groundwater monitoring (40 CFR 265.93 [d]) in June 1996 when elevated conductivity in downgradient monitoring well 299-E33-32 was confirmed by verification sampling. A rise in conductivity was initially observed in this well in February 1996.


Groundwater Quality Assessment Plan for Single-Shell Tank Waste Management Area U, Interim Change Notice 2

Groundwater Quality Assessment Plan for Single-Shell Tank Waste Management Area U, Interim Change Notice 2

Author: Ronald M. Smith

Publisher:

Published: 2006

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

This ICN updates the assessment plan to reflect the current wells in the WMA U monitoring system and to revise the analyte list. This document was prepared under the Groundwater Remediation and Closure Assessment Projects, and reflects the requirements of the Groundwater Performance Assessment Project Quality Assurance Plan (PNNL-15014).


Results of Phase 1 Groundwater Quality Assessment for Single-Shell Tank Waste Management Areas B-BX-BY at the Hanford Site

Results of Phase 1 Groundwater Quality Assessment for Single-Shell Tank Waste Management Areas B-BX-BY at the Hanford Site

Author:

Publisher:

Published: 2001

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

Pacific Northwest National Laboratory conducted a Phase 1 (or first determination) groundwater quality assessment for the US Department of Energy, Richland Operations Office, in accordance with the Federal Facility Compliance Agreement. The purpose of the assessment was to determine if the Single-Shell Tank Waste Management Area (WMA) B-BX-BY has impacted groundwater quality. This report will document the evidence demonstrating that the WMA has impacted groundwater quality.


Results of Phase I Groundwater Quality Assessment for Single-shell Tank Waste Management Area S-SX at the Hanford Site

Results of Phase I Groundwater Quality Assessment for Single-shell Tank Waste Management Area S-SX at the Hanford Site

Author:

Publisher:

Published: 2001

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

Pacific Northwest National Laboratory (PNNL) conducted a Phase I, Resource Conservation and Recovery Act of 1976 (RCRA) groundwater quality assessment for the Richland Field Office of the U.S. Department of Energy (DOE-RL), in accordance with the Federal Facility Compliance Agreement. The purpose of the investigation was to determine if the Single-Shell Tank Waste Management Area (WMA) S-SX has impacted groundwater quality. The WMA is located in the southern portion of the 200 West Area of the Hanford Site and consists of the 241-S and 241-SX tank farms and ancillary waste systems. The unit is regulated under RCRA interim-status regulations (40 CFR 265, Subpart F) and was placed in assessment groundwater monitoring (40 CFR 265.93[d]) in August 1996 because of elevated specific conductance and technetium-99, a non-RCRA co-contaminant, in downgradient monitoring wells. Major findings of the assessment are summarized below: (1) Distribution patterns for radionuclides and RCRA/dangerous waste constituents indicate WMA S-SX has contributed to groundwater contamination observed in downgradient monitoring wells. (2) Drinking water standards for nitrate and technetium-99 are currently exceeded in one RCRA-compliant well (299-W22-46) located at the southeastern comer of the SX tank farm. (3) Technetium-99, nitrate, and chromium concentrations in downgradient well 299-W22-46 (the well with the highest current concentrations) appear to be declining after reaching maximum concentrations in May 1997. (4) Cesium-137 and strontium-90, major constituents of concern in single-shell tank waste, were not detected in any of the RCRA-compliant wells in the WMA network, including the well with the highest current technetium-99 concentrations (299-W22-46). (5) Low but detectable strontium-90 and cesium-137 were found in one old well (2-W23-7), located inside and between the S and SX tank farms.