Manganese Removal from Groundwater

Manganese Removal from Groundwater

Author: J.H. Bruins

Publisher: CRC Press

Published: 2017-03-16

Total Pages: 162

ISBN-13: 1351652508

DOWNLOAD EBOOK

In The Netherlands, Belgium and other European countries, manganese is removed by conventional groundwater treatment with aeration and rapid (sand) filtration. Such a treatment process is easy to operate, cost effective and sustainable, because it does not make use of strong oxidants such as O3, Cl2, ClO2 and KMnO4 with the associated risk of by-product formation and over or under dosing. However, application of aeration-filtration is also facing drawbacks, especially the long ripening time of filter media. Due to the long ripening time, water companies have to waste large volumes of treated water, making this process less sustainable. Also, costs associated with filter media ripening (man power, electricity, operational and analysis costs) are high. Therefore decreasing the filter ripening time, regarding manganese removal is a big issue. Although already extended research has been carried out into manganese removal, the controlling mechanisms, especially of the start up face of filter media ripening, are not fully understood yet. The emphasis of this thesis is to provide a better understanding of the mechanisms involved in the ripening of virgin filter media, regarding manganese removal and how to shorten or completely eliminate the long ripening period of filters with virgin material. This thesis therefore highlights the role of the formation of a manganese oxide coating on virgin filter media. Characterization and identification revealed that the responsible manganese oxide for an effective manganese removal was Birnessite. It was found that Birnessite, formed at the beginning of the ripening process was of a biological origin. Based on the knowledge that manganese removal in conventional groundwater treatment is initiated biologically, long ripening times may be reduced by creating conditions favouring the growth of manganese oxidizing bacteria, e.g., by limiting the back wash frequency and / or intensity. Additionally, this thesis also shows that the use of freshly prepared manganese oxide, containing Birnessite, can completely eliminate filter media ripening time.


Occurrence of Manganese in Drinking Water and Manganese Control

Occurrence of Manganese in Drinking Water and Manganese Control

Author: Paul M. Kohl

Publisher: American Water Works Association

Published: 2006

Total Pages: 460

ISBN-13: 1583215042

DOWNLOAD EBOOK

This research study describes the chemistry and suggested treatment of manganese in drinking water, with the goals of reducing customer complaints and improving perceived water quality. The problems are aesthetic-water discoloration (usually black or dark red), clothing and fixture staining, turbid water sediments, and, at very high levels, metallic taste.


Water Quality Monitoring

Water Quality Monitoring

Author: Jamie Bartram

Publisher: CRC Press

Published: 2020-10-14

Total Pages: 396

ISBN-13: 1000101606

DOWNLOAD EBOOK

Water quality monitoring is an essential tool in the management of water resources and this book comprehensively covers the entire monitoring operation. This important text is the outcome of a collborative programme of activity between UNEP and WHO with inputs from WMO and UNESCO and draws on the international standards of the International Organization of Standardization.


Ozone in Water Treatment

Ozone in Water Treatment

Author: Am Water Works Res F

Publisher: CRC Press

Published: 1991-02-13

Total Pages: 602

ISBN-13: 9780873714747

DOWNLOAD EBOOK

With the advent of the Safe Drinking Water Act Amendments of 1986, many water utilities are reexamining their water treatment practices. Upcoming new regulations on disinfection and on disinfection by-products, in particular, are the primary driving forces for the big interest in ozone. It appears that ozone, with its strong disinfection capabilities, and apparently lower levels of disinfection by-products (compared to other disinfectants), may be the oxidant/disinfectant of choice. Many utilities currently using chlorine for oxidation may need to switch due to chlorine by-product concerns. Utilities using chloramines may need to use ozone to meet CT requirements. This book, prepared by 35 international experts, includes current technology on the design, operation, and control of the ozone process within a drinking water plant. It combines almost 100 years of European ozone design and operating experience with North American design/operations experience and the North American regulatory and utility operational environment. Topics covered include ozone chemistry, toxicology, design consideration, engineering aspects, design of retrofit systems, and the operation and economics of ozone technology. The book contains a "how to" section on ozone treatability studies, which explains what information can be learned using treatability studies, at what scale (bench, pilot, or demonstration plant), and how this information can be used to design full-scale systems. It also includes valuable tips regarding important operating practices, as well as guidance on retrofits and the unique issues involved with retrofitting the ozone process. With ozone being one of the hottest areas of interest in drinking water, this book will prove essential to all water utilities, design engineers, regulators, and plant managers and supervisors.


Adsorptive Iron Removal from Groundwater

Adsorptive Iron Removal from Groundwater

Author: Sharoz Kumar Sharma

Publisher: CRC Press

Published: 2021-05-30

Total Pages: 216

ISBN-13: 1000445577

DOWNLOAD EBOOK

A pilot study conducted at the Gilze water treatment plant of Water Supply North West Brabant demonstrated that adsorptive filtration has several potential advantages over floc filtration, namely: longer filter runs due to slower head loss development; better filtrate quality; shorter ripening time; and less backwash water use. In existing groundwater treatment plants, the high iron (II) adsorption capacity of the iron oxide coated filter media makes it potentially possible to switch the governing mode of operation from floc filtration to adsorptive filtration. To achieve this two options can be considered: iron (II) adsorption under anoxic conditions followed by oxidation with oxygen-rich water; and adsorption of iron (II) in the presence of oxygen and simultaneous oxidation. The first option might be attractive specifically when two filtration steps are available.


Water Governance

Water Governance

Author: R.K. Mishra

Publisher: Allied Publishers

Published: 2013-01-15

Total Pages: 267

ISBN-13: 8184247524

DOWNLOAD EBOOK

This present volume contains 18 contributions, papers presented in four technical sessions during the national seminar on Governance and Management of water. The volume analyses the present crisis of water from different aspects and provides an opportunity to address the challenges on effective water governance and management. By focusing on different cases from around the country, the colume generates new ideas and hopes for probable of such challenges.


Occurrence and Distribution of Iron, Manganese, and Selected Trace Elements in Ground Water in the Glacial Aquifer System of the Northern United States

Occurrence and Distribution of Iron, Manganese, and Selected Trace Elements in Ground Water in the Glacial Aquifer System of the Northern United States

Author:

Publisher:

Published: 2009

Total Pages: 108

ISBN-13:

DOWNLOAD EBOOK

Dissolved trace elements, including iron and manganese, are often an important factor in use of ground water for drinking-water supplies. Concentrations of these trace elements can very over several orders of magnitude across local well networks as well as across regions of the United States.