Guide to Verification and Validation of the SCALE-4 Criticality Safety Software

Guide to Verification and Validation of the SCALE-4 Criticality Safety Software

Author:

Publisher:

Published: 1996

Total Pages: 114

ISBN-13:

DOWNLOAD EBOOK

Whenever a decision is made to newly install the SCALE nuclear criticality safety software on a computer system, the user should run a set of verification and validation (V & V) test cases to demonstrate that the software is properly installed and functioning correctly. This report is intended to serve as a guide for this V & V in that it specifies test cases to run and gives expected results. The report describes the V & V that has been performed for the nuclear criticality safety software in a version of SCALE-4. The verification problems specified by the code developers have been run, and the results compare favorably with those in the SCALE 4.2 baseline. The results reported in this document are from the SCALE 4.2P version which was run on an IBM RS/6000 workstation. These results verify that the SCALE-4 nuclear criticality safety software has been correctly installed and is functioning properly. A validation has been performed for KENO V.a utilizing the CSAS25 criticality sequence and the SCALE 27-group cross-section library for 233U, 235U, and 239Pu fissile, systems in a broad range of geometries and fissile fuel forms. The experimental models used for the validation were taken from three previous validations of KENO V.a. A statistical analysis of the calculated results was used to determine the average calculational bias and a subcritical k{sub eff} criteria for each class of systems validated. Included the statistical analysis is a means of estimating the margin of subcriticality in k{sub eff}. This validation demonstrates that KENO V.a and the 27-group library may be used for nuclear criticality safety computations provided the system being analyzed falls within the range of the experiments used in the validation.


Criticality Safety Validation of SCALE 6.1 with ENDF/B-VII.0 Libraries

Criticality Safety Validation of SCALE 6.1 with ENDF/B-VII.0 Libraries

Author:

Publisher:

Published: 2012

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

ANSI/ANS-8.1-1998;2007, Nuclear Criticality Safety in Operations with Fissionable Material Outside Reactors, and ANSI/ANS-8.24-2007, Validation of Neutron Transport Methods for Nuclear Criticality Safety Calculations, require validation of a computer code and the associated data through benchmark evaluations based on physical experiments. The performance of the code and data are validated by comparing the calculated and the benchmark results. A SCALE procedure has been established to generate a Verified, Archived Library of Inputs and Data (VALID). This procedure provides a framework for preparing, peer reviewing, and controlling models and data sets derived from benchmark definitions so that the models and data can be used with confidence. The procedure ensures that the models and data were correctly generated using appropriate references with documented checks and reviews. Configuration management is implemented to prevent inadvertent modification of the models and data or inclusion of models that have not been subjected to the rigorous review process. VALID entries for criticality safety are based on critical experiments documented in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). The findings of a criticality safety validation of SCALE 6.1 utilizing the benchmark models vetted in the VALID library at Oak Ridge National Laboratory are summarized here.