Corrosion Protection Performance of Corrosion Inhibitors and Epoxy-coated Reinforcing Steel in a Simulated Concrete Pore Water Solution

Corrosion Protection Performance of Corrosion Inhibitors and Epoxy-coated Reinforcing Steel in a Simulated Concrete Pore Water Solution

Author: Wioleta A. Pyć

Publisher:

Published: 1998

Total Pages: 58

ISBN-13:

DOWNLOAD EBOOK

We used a simulated concrete pore water solution to evaluate the corrosion protection performance of concrete corrosion-inhibiting admixtures and epoxy-coated reinforcing bars (ECR). We evaluated three commercial corrosion inhibitors, ECR from three coaters removed from job sites, one ECR shipped directly from the coater's plant, and one ECR removed from a job site plus a corrosion inhibitor. The corrosion inhibitors were calcium nitrite, an aqueous mixture of esters and amines, and a mixture of alcohol and amine. Corrosion protection performance was based on the amount of visually observed corroded surface area. For bare steel tested with and without corrosion inhibitors, corrosion increased with increasing chloride concentration, and specimens saturated with oxygen were more corroded than specimens saturated with breathing air. The amount of corrosion over the 90-day test period was controlled by the amount of oxygen in solution at the higher chloride concentrations. The ester-amine and alcohol-amine did not inhibit corrosion. Calcium nitrite inhibited corrosion at all levels of chloride concentration. For ECR, corrosion occurred both at sites where the coating was damaged and underneath the coating. Coating debondment was greatest in pore water solutions containing chloride. The least coating debondment and corrosion occurred in the solution containing calcium nitrite and the ECR shipped directly from the manufacturer. Coating debondment and corrosion of ECR are directly related to the amount of damage as holes; mashed, dented, and cracked areas; and holidays. The researchers recommend that the developed test method be adopted as a standard test for concrete corrosion inhibitors and that calcium nitrite remain the only concrete corrosion inhibitor approved for use in Virginia.


New Challenges and Industrial Applications for Corrosion Prevention and Control

New Challenges and Industrial Applications for Corrosion Prevention and Control

Author: El Kacimi, Younes

Publisher: IGI Global

Published: 2020-06-12

Total Pages: 304

ISBN-13: 1799827771

DOWNLOAD EBOOK

Metals are used at an extremely high rate in the industrial and manufacturing fields. Exemplary properties including strength and ductility have made this material highly dynamic; however, the risk of corrosion remains a vital issue. The study of corrosion prevention has attracted interest from researchers and professionals as new technologies are emerging that can assist in the prevention of material destruction. However, research is lacking on the application of these protective technologies within specific fields. New Challenges and Industrial Applications for Corrosion Prevention and Control provides emerging research exploring the theoretical and practical aspects of protective methods against corrosion and the implementation of these techniques within a wide span of professional disciplines. Featuring coverage on a broad range of topics such as molecular modeling, surface treatments, and biomaterials, this book is ideally designed for engineers, industrial chemists, material scientists, researchers, engineers, academicians, practitioners, and students seeking current research on the technological advancements in corrosion protection in various professional scopes.


Performance Evaluation of Corrosion Inhibitors and Galvanized Steel in Concrete Exposure Specimens

Performance Evaluation of Corrosion Inhibitors and Galvanized Steel in Concrete Exposure Specimens

Author: Jerzy Zemajtis

Publisher:

Published: 1999

Total Pages: 80

ISBN-13:

DOWNLOAD EBOOK

Corrosion inhibitor admixtures (CIA) and galvanized reinforcing steel (GS) are used for the corrosion protection for reinforced concrete bridges. The results of a 3.5-year evaluation of exposure specimens containing CIA from three different manufacturers and GS are presented. The specimens were built to simulate four exposure conditions typical for concrete bridges located in the coastal region or inland where deicing salts are used. The exposure conditions were Horizontal, Vertical, Tidal, and Immersed Zones. The specimens were kept inside the laboratory and were exposed to weekly ponding cycles of 6% sodium chloride solution by weight. The methods used to assess the condition of the specimens included chloride concentration measurements, corrosion potentials, and corrosion rates. Additionally, visual observations were performed for identification of rust stains and cracking on concrete surfaces. The results of chloride testing indicate that the amount of chlorides present at the bar level is more than sufficient to initiate corrosion. Chloride and rapid permeability data indicate no significant difference either in a rate of chloride ingress or in the diffusion coefficients for concretes with and without CIA. Corrosion potentials were the most negative for the Bare Steel (BS) specimen prepared with the Armatec 2000 corrosion inhibitor and generally indicated a 90% probability of active corrosion. Corrosion potentials were similar for the two BS control specimens and the BS specimen prepared with Rheocrete 222 and generally indicated an uncertain probability of corrosion. Corrosion potentials were the least negative for the BS specimen prepared with DCI-S corrosion inhibitor and generally indicated a 90% probability of no corrosion. Rate of corrosion measurements were the highest for the BS control specimens and the one prepared with A2000 and the most recent data suggest corrosion damage in 2 to 10 years. Although early rate of corrosion measurements were higher or about the same as for BS control specimens, recent measurements were slightly lower for the specimen prepared with Rheocrete 222 and suggest corrosion damage in 10 to 15 years. Rate of corrosion measurements were consistently the lowest for the BS specimens prepared with DCI-S and indicate corrosion damage is expected in 10 to 15 years. The corrosion potential and rate of corrosion data indicate that DCI-S is the only CIA evaluated that clearly provides some level of corrosion protection. A direct comparison of the GS specimens to the BS specimens is not possible because the measured potential refers to the zinc oxide and not to the steel. Nevertheless, the potential data agree with the chloride and permeability data, as well as with the visual observations, and indicate the damaging effect of a high concentration of chloride ions on the GS. At low and moderate chloride exposures, however, GS does provide corrosion protection. Recommendations are to continue monitoring until sufficient cracking has occurred in all specimens to provide for making a better estimate of the service lives of CIA and GS used in the construction of concrete bridge components in Virginia. The specimens with CIA and one control (continuous reinforcement in the legs) should be taken to the Hampton Road North Tunnel Island and placed in the brackish water to a depth of the Immersed Zone at low tide for further exposure to chloride. The specimens with GS and the other control (non-continuous reinforcement in the legs) should remain in an outdoor exposure in Southwest Virginia like the Civil Engineering Materials Research Laboratory in Blacksburg, Virginia.


An Evaluation of New Inhibitors for Rebar Corrosion in Concrete

An Evaluation of New Inhibitors for Rebar Corrosion in Concrete

Author: Brian D. Chambers

Publisher:

Published: 2003

Total Pages: 68

ISBN-13:

DOWNLOAD EBOOK

The corrosion of reinforcing steel in concrete is estimated to affect more than 50% of the 575,000 bridges in the United States. One approach to mitigating this problem is to use corrosion-inhibitive compounds admixed into the concrete paste. This study sought to examine the corrosion inhibition performance of a series of compounds admixed into high-quality concrete and to delineate the effects of these compounds on the concrete with regard to the corrosion process. A series of eight compounds were admixed into Type A4 concrete. The compounds tested were aminoethylethanolamine, aminothiophenol, di-sodium Beta-glycerophosphate, calcium nitrite, di-n-butyl sulfoxide, lithium nitrate, sodium metasilicate, and nitrilotriphosphonic acid. Concrete blocks were cast, into which were placed 0.009-in.-diameter 1040 steel wires. The corrosion rate was assessed via a resistance change measurement (RCM) of these wires over time using a temperature-corrected four-point resistance measurement. The time-to-open circuit for the wires was also monitored. RCM was compared to (1) electrochemical impedance spectroscopy results of tests conducted in a simulated pore solution, and (2) chloride permeability measurements of the concrete as per ASTM C 1202. The effect of the admixtures on the compressive strength and density of the concrete was also assessed. RCM and time-to-open circuit results showed that four test inhibitors had equal or better corrosion prevention at 2 years of testing compared to a widely used commercial mix (DCI). These test inhibitors included di-sodium Beta-glycerophosphate (0.283 mol/cu ft and 0.815 mol/cu ft), aminoethylethanolamine (0.815 mol/cu ft), lithium nitrate (0.815 mol/cu ft), and sodium metasilicate (0.815 mol/cu ft). After 100 weeks, 33% to 44% of the wires were active in concrete admixed with these test compounds, whereas only 25% of the wires were active in concrete admixed with DCI. This research has also shown that the performance of a corrosion inhibitor in high-quality concrete is a function of numerous interrelated factors that are not predicted from any single laboratory test. These tests provide promising results for alternative inhibitive admixtures for standard Type A4 concrete. It is recommended that additional tests be conducted on concrete mixtures containing slag and fly ash using multiple concentrations of the four most promising inhibitors. Further testing may lead to the implementation of a better corrosion-inhibiting admixture, thus increasing the service life of bridges.


10th International Symposium on the Conservation of Monuments in the Mediterranean Basin

10th International Symposium on the Conservation of Monuments in the Mediterranean Basin

Author: Maria Koui

Publisher: Springer

Published: 2018-11-30

Total Pages: 674

ISBN-13: 331978093X

DOWNLOAD EBOOK

This book addresses physical, chemical, and biological methods for the preservation of ancient artifacts. Advanced materials are required to preserve the Mediterranean belt's historic, artistic and archaeological relics against weathering, pollution, natural risks and anthropogenic hazards. Based upon the 10th International Symposium on the Conservation of Monuments in the Mediterranean Basin, this book provides a forum for international engineers, architects, archaeologists, conservators, geologists, art historians and scientists in the fields of physics, chemistry and biology to discuss principles, methods, and solutions for the preservation of global historical artifacts.


Corrosion Inhibitors for Steel in Concrete

Corrosion Inhibitors for Steel in Concrete

Author: Bernhard Elsener

Publisher: CRC Press

Published: 2001

Total Pages: 84

ISBN-13:

DOWNLOAD EBOOK

The use of inhibitors for rehabilitation of reinforced concrete structures is a new field of application and this new volume provides a State of the Art Report on this subject. Corrosion of steel in concrete is one of the major problems for infrastructure such as bridges, tunnels, housing etc. since it leads to spalling of the concrete and loss in cross section of the steel that may cause structural and safety problems. The steel in concrete generally resists corrosion as a result of a passive layer that develops on the metal surface in the alkaline environment of the concrete. Corrosion can occur if these conditions are disturbed, for example, in the presence of chlorides or with carbonation of concrete. Traditional repair methods consist in removing the deteriorated concrete and replacing it but these can be laborious, noisy and very costly. To avoid these disadvantages new methods have been developed in recent years. These include electrochemical procedures and, increasingly, the use of inhibitors. The use of inhibitors for rehabilitation of reinforced concrete structures is a new field of application and this new volume provides a State of the Art Report on this subject.The report, under the editorship of Prof. Bernhard Elsener, was prepared by a Task Group of the EFC Working Party on Corrosion of Reinforcement in Concrete. In a literature review it describes inorganic and organic chemicals that have been proposed and examined as well as the commercial corrosion inhibitors that are available on the market. Protection mechanism and possible effects of inhibitors on concrete properties are described. Practical experience with inhibitors for steel in concrete and the long term effectiveness are considered. The various test methods for evaluating the behaviour of the inhibitors are described and critically assessed. In a rapidly evolving field this State of the Art Report, based mainly on independent not commercial literature, will be of value to corrosion engineers and civil engineers concerned with maintenance and repair of reinforced concrete structures.


Corrosion of Steel in Concrete Structures

Corrosion of Steel in Concrete Structures

Author: Amir Poursaee

Publisher: Woodhead Publishing

Published: 2023-02-20

Total Pages: 400

ISBN-13: 0323851320

DOWNLOAD EBOOK

Essential reading for researchers, practitioners, and engineers, this book covers not only all the important aspects in the field of corrosion of steel reinforced concrete but also discusses new topics and future trends. Theoretical concepts of corrosion of steel in concrete structures, the variety of reinforcing materials and concrete, including stainless steel and galvanized steel, measurements and evaluations, such as electrochemical techniques and acoustic emission, protection and maintenance methods, and modelling, latest developments, and future trends in the field are discussed. - Comprehensive coverage of the corrosion of steel bars in concrete, investigating the range of reinforcing materials, and types of concrete - Introduces the latest measuring methods, data collection, and advanced modeling techniques - Second edition covers a range of new, emerging topics such as the concept of chloride threshold value, concrete permeability and chloride diffusion, the role of steel microstructure, and innovations in corrosion detection devices