Faults and Gravity Anomalies Over the East Mesa Hydrothermal-geothermal System

Faults and Gravity Anomalies Over the East Mesa Hydrothermal-geothermal System

Author:

Publisher:

Published: 1986

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

Detailed interpretations of gravity anomalies over geothermal systems may be extremely useful for mapping the fracture or fault systems that control the circulation of the thermal waters. This approach seems to be particularly applicable in areas like the Salton Trough where reactions between the thermal waters and the porous sediments produce authigenic-hydrothermal minerals in sufficient quantity to cause distinct gravity anomalies at the surface. A 3-D inversion of the residual Bouguer gravity anomaly over the East Mesa geothermal field was made to examine the densified volume of rock. We show that the data not only resolve a north-south and an intersecting northwest structure, but that it may be possible to distinguish between the active present-day hydrothermal system and an older and cooler part of the system. The densified region is compared spatially to self-potential, thermal and seismic results and we find a good concordance between the different geophysical data sets. Our results agree with previous studies that have indicated that the main feeder fault recharging the East Mesa reservoir dips steeply to the west.


Scientific and Technical Aerospace Reports

Scientific and Technical Aerospace Reports

Author:

Publisher:

Published: 1987

Total Pages: 1126

ISBN-13:

DOWNLOAD EBOOK

Lists citations with abstracts for aerospace related reports obtained from world wide sources and announces documents that have recently been entered into the NASA Scientific and Technical Information Database.


Geothermal Well Test Analysis

Geothermal Well Test Analysis

Author: Sadiq J. Zarrouk

Publisher: Academic Press

Published: 2019-04-30

Total Pages: 367

ISBN-13: 0128149477

DOWNLOAD EBOOK

Geothermal Well Test Analysis: Fundamentals, Applications and Advanced Techniques provides a comprehensive review of the geothermal pressure transient analysis methodology and its similarities and differences with petroleum and groundwater well test analysis. Also discussed are the different tests undertaken in geothermal wells during completion testing, output/production testing, and the interpretation of data. In addition, the book focuses on pressure transient analysis by numerical simulation and inverse methods, also covering the familiar pressure derivative plot. Finally, non-standard geothermal pressure transient behaviors are analyzed and interpreted by numerical techniques for cases beyond the limit of existing analytical techniques. Provides a guide on the analysis of well test data in geothermal wells, including pressure transient analysis, completion testing and output testing Presents practical information on how to avoid common issues with data collection in geothermal wells Uses SI units, converting existing equations and models found in literature to this unit system instead of oilfield units


A Fault-Zone Controlled Model of the Mesa Anomaly

A Fault-Zone Controlled Model of the Mesa Anomaly

Author:

Publisher:

Published: 1977

Total Pages:

ISBN-13:

DOWNLOAD EBOOK

Recent studies of liquid-dominated systems suggest that geothermal anomalies are intimately associated with specific patterns of faulting. One may infer from these studies that the East Mesa anomaly is intersected by a seismically active fault which acts as a conduit of heated water from depth. This paper describes such a model of the Mesa system. 28 refs.